Representative ME-L photo; labels may vary by model.
Reader modules · Impinj E310 / Impinj E710
IDRO900ME-L Series UHF RFID Reader Module
IDRO900ME-L is a UHF RAIN RFID reader module in a 36.0 × 40.5 × 7.7 mm, 16 g die-cast housing. ME-L uses the Impinj E710 and ME-L3 uses the Impinj E310. It delivers up to +30 dBm output over a UART host interface, with 40 mA standby and a PWR_ON shutdown (300 nA) for battery-powered devices.
Best suited for
- Handheld and mobile readers where standby power matters
- Designs using an external antenna on a microFL connector
- ME-L (E710) for high multi-tag throughput; ME-L3 (E310) when cost and power come first
Specifications
| Item | ME-L | ME-L3 |
|---|---|---|
| RFID chip | Impinj E710 | Impinj E310 |
| Protocol | ISO 18000-63 / EPCglobal Gen2v2, Impinj Gen2X support (FastID, TagFocus, Protected Mode, etc.) | ISO 18000-63 / EPCglobal Gen2v2, Impinj Gen2X support (FastID, TagFocus, Protected Mode, etc.) |
| Rx sensitivity (chip) | −98 dBm ¹ | −84 dBm ¹ |
| Multi-tag read rate (chip) | 1,100+ tags/s ¹ | 250 tags/s ² |
| Frequency | 860–930 MHz | 860–930 MHz |
| Max output | +30 dBm | +30 dBm |
| Supply current | 1,300 mA @ +30 dBm / standby 40 mA / PWR_ON shutdown 300 nA | 1,300 mA @ +30 dBm / standby 40 mA / PWR_ON shutdown 300 nA |
| Supply voltage | 3.8–4.2 V | 3.8–4.2 V |
| Host interface | UART 9.6–921.6 kbps (default 921.6), RTS/CTS, GPIO ×2 | UART 9.6–921.6 kbps (default 115.2), RTS/CTS, GPIO ×2 |
| Antenna connector | microFL | microFL |
| Size · weight | 36.0 × 40.5 × 7.7 mm · 16 g | 36.0 × 40.5 × 7.7 mm · 16 g |
| Housing | Die-cast aluminium | Die-cast aluminium |
| Read range | max. 14 m ³ | — |
| Operating / storage temp. | −20 ~ +55 °C / −30 ~ +100 °C | −20 ~ +55 °C / −30 ~ +100 °C |
Reliability tests: high-temp storage 100 °C 48 h, low-temp storage −30 °C 48 h, high-temp operation +60 °C 12 h, low-temp operation −20 °C 12 h, thermal shock 12 cycles, ESD ±4 kV contact / ±8 kV air.
Certifications
| Item | Certifications |
|---|---|
| ME-L | KC R-C-DRO-IDRO900ME-L, FCC ID XVY-IDRO900ME-L, CE, TELEC 011-240008 |
| ME-L3 | KC R-C-DRO-IDRO900ME-L3, TELEC 011-250064 |
Before integration
Sensitivity and read rate are chip specifications. Actual performance depends on tags, antennas, installation and settings. Certifications apply to the listed model and scope; confirm end-product integration and regional operating requirements.
The module has one RF connection. ME-T/ME-U four-port evaluation requires a separate four-port EVM. Chip compatibility does not guarantee a drop-in module replacement.
Sources and test conditions
- ¹ Impinj E910/E710/E510/E310 Reader Chip Datasheet v6 (2026-11-06), public chip specification measured at the chip receive pin. Not a module or reader measurement.
- ² Impinj Reader Chip Portfolio public specification. Chip-level value; test conditions differ from the Ex10 datasheet.
- ³ Outdoor, single tag, IDRO patch antenna. Maximum range depends on tag performance and installation.
Specifications as of: 2026-11-26