IDRO900ME-L Series UHF RFID Reader Module

IDRO900ME-L is a UHF RAIN RFID reader module in a 36.0 × 40.5 × 7.7 mm, 16 g die-cast housing. ME-L uses the Impinj E710 and ME-L3 uses the Impinj E310. It delivers up to +30 dBm output over a UART host interface, with 40 mA standby and a PWR_ON shutdown (300 nA) for battery-powered devices.

Best suited for

  • Handheld and mobile readers where standby power matters
  • Designs using an external antenna on a microFL connector
  • ME-L (E710) for high multi-tag throughput; ME-L3 (E310) when cost and power come first

Specifications

ItemME-LME-L3
RFID chipImpinj E710Impinj E310
ProtocolISO 18000-63 / EPCglobal Gen2v2, Impinj Gen2X support (FastID, TagFocus, Protected Mode, etc.)ISO 18000-63 / EPCglobal Gen2v2, Impinj Gen2X support (FastID, TagFocus, Protected Mode, etc.)
Rx sensitivity (chip)−98 dBm ¹−84 dBm ¹
Multi-tag read rate (chip)1,100+ tags/s ¹250 tags/s ²
Frequency860–930 MHz860–930 MHz
Max output+30 dBm+30 dBm
Supply current1,300 mA @ +30 dBm / standby 40 mA / PWR_ON shutdown 300 nA1,300 mA @ +30 dBm / standby 40 mA / PWR_ON shutdown 300 nA
Supply voltage3.8–4.2 V3.8–4.2 V
Host interfaceUART 9.6–921.6 kbps (default 921.6), RTS/CTS, GPIO ×2UART 9.6–921.6 kbps (default 115.2), RTS/CTS, GPIO ×2
Antenna connectormicroFLmicroFL
Size · weight36.0 × 40.5 × 7.7 mm · 16 g36.0 × 40.5 × 7.7 mm · 16 g
HousingDie-cast aluminiumDie-cast aluminium
Read rangemax. 14 m ³—
Operating / storage temp.−20 ~ +55 °C / −30 ~ +100 °C−20 ~ +55 °C / −30 ~ +100 °C

Reliability tests: high-temp storage 100 °C 48 h, low-temp storage −30 °C 48 h, high-temp operation +60 °C 12 h, low-temp operation −20 °C 12 h, thermal shock 12 cycles, ESD ±4 kV contact / ±8 kV air.

Certifications

ItemCertifications
ME-LKC R-C-DRO-IDRO900ME-L, FCC ID XVY-IDRO900ME-L, CE, TELEC 011-240008
ME-L3KC R-C-DRO-IDRO900ME-L3, TELEC 011-250064

Before integration

Sensitivity and read rate are chip specifications. Actual performance depends on tags, antennas, installation and settings. Certifications apply to the listed model and scope; confirm end-product integration and regional operating requirements.

The module has one RF connection. ME-T/ME-U four-port evaluation requires a separate four-port EVM. Chip compatibility does not guarantee a drop-in module replacement.